MEGA POWER INC -- CARB CLEANER, 76 -- 7930-00N057359
===================== Product Identification =====================
Product ID:CARB CLEANER, 76
MSDS Date:02/15/1994
FSC:7930
NIIN:00N057359
=== Responsible Party ===
Company Name:MEGA POWER INC
Box:98
City:PINELLAS PARK
State:FL
ZIP:34290-0098
Country:US
Info Phone Num:813-572-0449
Emergency Phone Num:813-572-0449
CAGE:IO982
=== Contractor Identification ===
Company Name:MEGA POWER CO
Box:City:PINELLAS PARK
State:FL
ZIP:34290-0098
Country:US
Phone:813-572-0449
CAGE:MEGAX
Company Name:MEGA POWER INC
Box:98
City:PINELLAS PARK
State:FL
ZIP:34290-0098
Country:US
Phone:813-572-0449
CAGE:IO982
============= Composition/Information on Ingredients =============
Ingred Name:XYLENE (SARA 313) (CERCLA). VP:36.7 @ 30C.
CAS:1330-20-7
RTECS #:ZE2100000
OSHA PEL:200 PPM
ACGIH TLV:50 PPM, S
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:METHYL ALCOHOL (METHANOL); (KETONES) (SARA 313) (CERCLA).
VP:97.6 @ 20C.
CAS:67-56-1
RTECS #:PC1400000
OSHA PEL:200 PPM, S
ACGIH TLV:200 PPM;250 STEL, S
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:CARBON DIOXIDE; (CO*2) (PROPELLANT)
CAS:124-38-9
RTECS #:FF6400000
OSHA PEL:5000 PPM
ACGIH TLV:5000 PPM;30000 STEL
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:MAY CAUSE IRRIT OF RESP
TRACT, LABORED BRTHG, ANOREXIA, NAUS, VOMIT, FATG, HDCH, DIZZ,
IRRITABILITY, INCOORD & NARCOSIS. INTERNAL MISUSE OF THIS PROD BY
DELIB CONCENTRATING & INHALING CAN BE HARMFUL/FATAL. INGEST:MAY BE
FATAL/CAUSE BLINDNESS. MAY CAUSE MUSCULAR INCOORD, HDCH, DIZZ,
NAUS, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:VOMIT, ABDOM PAIN, SWEATING & WEAK.
SKIN:IRRIT TO EYES & SKIN. CHRONIC:MAY CAUSE SKIN IRRIT ON
PRLNG/RPTD CONT. REPORTS HAVE ASSOC RPTD & PLNG OVEREXP TO SOLVS
W/NEUROLOGICAL & OTHER PHYSIOLO GICAL DMG. MAY CAUSE VISUAL
IMPAIRMENT/BLINDNESS.
Medical Cond Aggravated by Exposure:DISEASES OF THE EYES, LIVER,
KIDNEYS, LUNGS, CENTRAL NERVOUS SYSTEM & BLOOD.
======================= First Aid Measures =======================
First Aid:INHAL:IF USER EXPERS BRTHG DFCTLY, MOVE TO AIR FREE OF VAPS.
ADMIN OXYGEN/ARTF RESP UNTIL MED ASSISTANCE CAN BE RENDERED.
INGEST:CALL YOUR HOSPITAL EMER ROOM, POIS CTL CTR/MD IMMED FOR
INSTRUCTIONS. E YE:FLUSH W/LG QTYS OF WATER FOR AT LST 15 MINS &
SEEK IMMED MED ATTN. SKIN:WASH W/SOAP & LG QTYS OF WATER & SEEK MED
ATTN IF IRRIT FROM CONTACT PERSISTS.
===================== Fire Fighting Measures =====================
Extinguishing Media:USE CARBON DIOXIDE, DRY POWDER OR FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . STORAGE CONTAINERS EXPOSED TO FIRE SHOULD BE KEPT COOL
W/WATER SPRAY.
Unusual Fire/Explosion Hazard:EXTREMELY FLAMMABLE. CONTENTS UNDER
PRESSURE. EXPOSURE TO HEAT OR PROLONGED EXPOSURE TO SUN CAN CAUSE
BURSTING.
================== Accidental Release Measures ==================
Spill Release Procedures:AVOID BREATHING VAPORS. VENTILATE AREA. FLUSH
LARGE SPILLS OF MATL INTO SUITABLE RETAINING AREA OR CONTAINERS
W/LARGE QUANTITIES OF WATER. SMALL SPILLS CAN BE ABSORBED BY
APPROPRIATE INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:ISOLATE FROM HEAT, ELEC EQUIP, SPARKS,
OPEN FLAMES & HOT SURFACES. DO NOT PUNCTURE, INCINERATE OR STORE
>120F. KEEP OUT OF REACH OF CHILDREN!
Other Precautions:READ CAREFULLY ALL CAUTIONS & DIRECTIONS ON LABEL
BEFORE USE. SINCE EMPTY CNTNR RETAINS RESIDUE, FOLLOW ALL LABEL
WARNINGS EVEN AFTER CNTNR IS EMPTY. DISPOSE OF EMPTY CNTNR
ACCORDING TO LOCAL REGULATI ONS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:FOR OCCASIONAL USE WHERE ENGINEERED AIR CONTROL
IS NOT FEASIBLE, USE NIOSH/MSHA APPROVED RESPIRATORS. FOR
OCCASIONAL CONSUMER USE, USE ONLY W/ADEQUATE VENTILATION.
Ventilation:ADEQ VENT MUST BE PROVIDED. FOR OSHA CONTROLLED WORK PLACE,
USE ONLY W/ADEQ VENT UNDER ENGINEERED AIR CONTROL (SUPDAT)
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . VARYING APPLICATION METHS CAN DICTATE
(SUPDAT)
Work Hygienic Practices:WASH HANDS THOROUGHLY AFTER USE.
Supplemental Safety and Health
VENT:SYSTEMS DESIGNED TO PROVIDE MAX APPROPRIATE TLV. EYE PROT:& FULL
LENGTH FACESHIELD . OTHER PROT EQUIP:USE OF ADDNL PROT SAFETY
EQUIP, SUCH AS IMPERMEABLE APRONS, ETC.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:>147F,>64C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.83
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE RECOGNIZED.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF I/A/W APPLICABLE LOCAL, STATE &
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.