AIRGAS INC -- CARBON DIOXIDE - CO*2 SOLID -- 6830-00N087728
=====================  Product Identification  =====================

Product ID:CARBON DIOXIDE - CO*2 SOLID
MSDS Date:10/31/1996
FSC:6830
NIIN:00N087728
=== Responsible Party ===
Company Name:AIRGAS INC
Address:259 RADNOR-CHESTER RD SUITE 100
City:RADNOR
State:PA
ZIP:19087-5240
Country:US
Info Phone Num:610-687-5253
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:JO188
=== Contractor Identification ===
Company Name:AIRGAS INC
Box:UNKNOW
CAGE:ARGAS
Company Name:AIRGAS INC
Address:100 MATSONFORD RD
Box:City:RADNOR
State:PA
ZIP:19087
Country:US
Phone:610-687-5253;610-687-5253
CAGE:JO188

=============  Composition/Information on Ingredients  =============

Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Fraction by Wt: >99.8%
OSHA PEL:5000 PPM
ACGIH TLV:5000 PPM;30000 STEL

Ingred Name:IMPURITIES
Fraction by Wt: <0.2%MAX
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SUPDAT:SOLID PROD W/SODIUM & POTASSIUM ALLOYS ARE IMPACT
    SENSITIVE & EXPLODE VIOLENTLY. IN PRESENCE OF MOISTURE, (ING 4)
RTECS #:9999999ZZ

Ingred Name:ING 3:CESIUM OXIDE IGNITES ON CONTACT W/PRODUCT. METAL
    ACETYLIDES OR HYDRIDES WILL ALSO IGNITE OR EXPLODE.
RTECS #:9999999ZZ

Ingred Name:EFTS OF OVEREXP:CONVULSIVE MOVEMENTS, POSS RESP COLLAPSE &
    DEATH. CO*2 CONCS - 10% OR MORE:SUFFOCATION; 2-10%: (ING 6)
RTECS #:9999999ZZ

Ingred Name:ING 5:NAUS, DIZZ, HDCH, MENTAL CONFUSN, INCR BLOOD PRESS &
    RESP RATE. CHRONIC:THERE ARE CURRENTLY NO KNOWN (ING 7)
RTECS #:9999999ZZ

Ingred Name:ING 6:ADVERSE HEALTH EFFECTS ASSOCIATED W/CHRONIC EXPOSURE
    TO THIS GAS. FOR MORE SPECIFIC INFO CONTACT NEHC .
RTECS #:9999999ZZ

Ingred Name:FIRST AID PROC:NOT USE HOT WATER. IF WARM WATER NOT
    AVAIL/IMPRACTICAL, WRAP AFFECTED PARTS GENTLY IN BLANKETS. (ING 9)
RTECS #:9999999ZZ

Ingred Name:ING 8:ALTERNATIVELY, IF FINGERS/HANDS ARE FROSTBITTEN,
    PLACE AFFECTED AREA IN ARMPIT. ENCOURAGE VICTIM TO GENTLY(ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9:EXERCISE AFFECTED PART WHILE BEING WARMED. SEEK IMMED
    MED ATTN. VICTIMS & RESCUERS(IF NEC) MUST BE TAKEN (ING 11)
RTECS #:9999999ZZ

Ingred Name:ING 10:FOR MEDICAL ATTENTION. TAKE COPY OF LABEL & MSDS TO
    MD OR OTHER HEALTH PROFESSIONAL W/VICTIM(S).
RTECS #:9999999ZZ

Ingred Name:SPILL PROC:SEAL SOURCE OF LEAKING GAS. PROT PERS ATTEMPTING
    SHUT-OFF W/WATER-SPRAY. ALLOW GAS, WHICH IS HVR/AIR,(ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12:TO DISSIPATE. MONITOR SURROUND AREA FOR OXYG LEVELS.
    ATM MUST HAVE AT LST 19.6% OXYG BEFORE PERS CAN BE (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13:ALLOWED IN AREA W/OUT NIOSH APPRVD SCBA. ATTEMPT TO
    CLOSE MAIN SOURCE VALVE PRIOR TO ENTERING AREA. IF (ING 15)
RTECS #:9999999ZZ

Ingred Name:ING 14:THIS DOES NOT STOP RELS/IF NOT POSS TO REACH VALVE,
    ALLOW GAS TO RELS IN-PLACE/REMOVE IT TO SAFE AREA & (ING 16)
RTECS #:9999999ZZ

Ingred Name:ING 15:ALLOW GAS TO BE RELS THERE. RELS OF LIQ PROD:CLEAR
    AFFECTED AREA & ALLOW LIQ TO EVAP & GAS TO DISSIPATE. (ING 17)
RTECS #:9999999ZZ

Ingred Name:ING 16:AFTER GAS IS FORMED, FOLLOW PREVIOUS INSTRUCTIONS.
    IF AREA MUST BE ENTERED BY EMER PERS, NIOSH APPRVD (ING 18)
RTECS #:9999999ZZ

Ingred Name:ING 17:SCBA, KEVLAR GLOVES & APPROPRIATE FOOT & LEG
    PROTECTION MUST BE WORN.
RTECS #:9999999ZZ

Ingred Name:OTHER PREC:STORE NEAR ELEVATORS, CORRIDORS/LOADING DOCKS.
    DO NOT ALLOW STOR AREA TO BE >51C(125F). USE ONLY STOR(ING 20)
RTECS #:9999999ZZ

Ingred Name:ING 19:CNTNRS & EQUIP DESIGNED FOR STOR OF SOLID,
    GASEOUS/LIQUEFIED PROD. DO NOT STORE CNTNRS WHERE THEY CAN (ING 21)
RTECS #:9999999ZZ

Ingred Name:ING 20:COME INTO CONT W/MOISTURE. CYLS SHOULD BE STORED
    UPRIGHT & BE FIRMLY SECURED TO PVNT FALLING/BEING (ING 22)
RTECS #:9999999ZZ

Ingred Name:ING 21:KNOCKED OVER. CYLS CAN BE STORED IN OPEN, BUT SHOULD
    BE PROT AGAINST WEATHER EXTREMES & DAMPNESS TO PVNT (ING 23)
RTECS #:9999999ZZ

Ingred Name:ING 22:RUSTING. NEVER TAMPER W/PRESS RELIEF DEVICES IN
    VALVES & CYLS. LIQUEFIED PROD MUST BE STORED & HNDLD (ING 24)
RTECS #:9999999ZZ

Ingred Name:ING 23:UNDER POS PRESS/IN CLSD SYS TO PVNT INFILTRATION &
    SOLIDIFICATION OF AIR/GASES. FOR MORE INFO CONT NEHC .
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MOST SIGNIFICANT HAZ ASSOC W/GAS
    IS INHAL OF OXYG-DEFICIENT ATMS. SYMPS OF OXYG DEFICIENCY INCL RESP
    DFCLTY, RINGING IN EARS, HDCHS, SHORTNESS OF BREATH, WHEEZING,
    HDCH, DIZZ, INDIGEST, NAUS, UN CON/DEATH. SKIN MAY HAVE BLUE COLOR.
    CONT W/RAPIDLY EXPANDING GASES (WHICH ARE RELS UNDER HIGH PRESS)
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:MAY CAUSE FROSTBITE. SYMPS OF
    FROSTBITE INCL CHANGE IN SKIN COLOR TO WHITE/GRAYISH-YELLOW. EFTS
    ASSOC W/VARIOUS LEVELS OF OXYG - 12-16%:BRTHG & PULSE RATE INCR,
    MUSC COORD SLIGHTLY DISTURBED;  10-14%:EMOTIONAL UPSET, ABNORM
    FATG, DISTURBED RESP; 6-10%:NAUS & VOMIT, COLLAPSE/LOSS OF
    CONSCIOUSNESS; <6%: (ING 5)
Medical Cond Aggravated by Exposure:PRE-EXISTING RESPIRATORY CONDITIONS
    MAY BE AGGRAVATED BY OVEREXPOSURE TO THIS PRODUCT.

=======================  First Aid Measures  =======================

First Aid:RESCUERS SHOULD NOT ATTEMPT TO RETRIEVE VICTIMS W/OUT ADEQ
    PPE. AT MIN, NIOSH APPRVD SCBA SHOULD BE WORN. INGEST:CALL MD
    IMMED. EYES:IMMED FLUSH W/POTABLE WATER FOR MIN OF 15 MINS, SEEK
    ASSISTAN CE FROM MD . INHAL:REMOVE TO FRESH AIR, AS QUICKLY AS
    POSS. ONLY TRAINED PERS SHOULD ADMIN SUPP OXYG &/OR CPR, IF NEC.
    SKIN:IN CASE OF FROSTBITE, PLACE FROSTBITTEN PART IN WARM WATER. DO
    (ING 8)

=====================  Fire Fighting Measures  =====================

Extinguishing Media:CARBON DIOXIDE IS COMMONLY USED AS EXTING AGENT -
    SHOULD NOT PRESENT PROB. USE EXTING MEDIA APPROP FOR SURROUNDING
    FIRE.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:DOES NOT BURN; HOWEVER, CNTNRS, WHEN
    INVOLVED IN FIRE, MAY RUPTURE/BURST IN HEAT OF FIRE. DUSTS OF
    VARIOUS REACTIVE METALS (E.G., MAGNESIUM, ZIRCON (SUPP DATA)

==================  Accidental Release Measures  ==================

Spill Release Procedures:UNCONTROLLED RELS SHOULD BE RESPONDED TO BY
    TRAINED PERS USING PRE-PLANNED PROCS. PPE SHOULD BE USED. CLEAN
    AFFECTED AREA, PROT PEOPLE & RESPOND W/TRAINED PERS. MIN PPE SHOULD
    BE PROT CLTHG, MECH-RESI ST GLOVES & NIOSH APPRVD SCBA. LOCATE
    &(ING 12)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE CYLS IN DRY, WELL-VENTED AREAS
    AWAY FROM SOURCES OF HEAT. COMPRESSED GASES CAN PRESENT SIGNIFICANT
    SFTY HAZS. PROT CYLS AGAINST PHYSICAL DMG.
Other Precautions:STORE CNTNRS AWAY FROM HEAVILY TRAFFICKED AREAS &
    EMER EXITS. POST "NO SMOKING/OPEN FLAMES" SIGNS IN STOR/USE AREAS.
    STORE SOLID PROD IN INSULATED CNTNRS WHICH OPEN FROM TOP & HAVE
    LOOSE FITTING LIDS	SO VAP MAY ESCAPE. DO NOT (ING 19)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:MAINTAIN OXYG LEVELS >19.5%. USE NIOSH APPRVD
    SUPPLIED AIR RESP PROT IF OXYG LEVELS ARE <19.5% OR DURING EMER
    RESPONSE TO RELS OF PROD. IF RESP PROT IS REQD, FOLLOW REQUIREMENTS
    OF FED OSHA (29 CFR 19 10.134), OR EQUIV STATE STDS.
Ventilation:USE W/ADEQ VENT. LOCAL EXHAUST VENT IS PREF. IF APPROP,
    INSTALL AUTOMATIC MONITORING EQUIP TO DETECT LEVEL OF OXYGEN.
Protective Gloves:MECH-RESIST GLOVES; LOW-TEMP (SUPP DATA)
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS &(SUPDAT)
Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE
    SHOWER . USE APPROP BODY PROT & PROT EQUIP. PROVIDE SUFFICIENT
    (SUPP DATA)
Work Hygienic Practices:AVOID GETTING PROD IN YOU. DO NOT EAT/DRINK
    WHILE HNDLG CHEMS. BE AWARE OF ANY SIGNS OF DIZZ/FATG; FATAL CONCS
    (SUPDAT)
Supplemental Safety and Health
PROT GLOVES:PROT GLOVES (E.G., INSULATED POLYVINYL CHLORIDE/INSULATED
    NITRILE). EYE PROT:FULL LGTH FSHLD . OTHER PROT EQUIP:INSULATION
    FROM EXTREME COLD. HYGIENE PRACT:COULD OCCUR W/OUT ANY SIGN IFICANT
    WARNING SYMPS. EXPLO HAZ:TITANIUM ALLOYS), ARE READILY IGNITED &
    EXPLODE IN PRESENCE OF PROD. MIXTS OF (ING 3)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:-109F,-79C
Melt/Freeze Pt:M.P/F.P Text:-70F,-57C
Vapor Pres:844.7 PSIA
Vapor Density:1.833
Spec Gravity:1.54
Solubility in Water:0.9% @ 20C.
Appearance and Odor:(DRY ICE) WHITE OPAQUE SOLID WHICH RELS COLORLESS,
    ODORLESS GAS.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
POWDERED ALUMINUM, BERYLLIUM, CERIUM ALLOYS, CHROMIUM,
    MAGNESIUM-ALUMINUM ALLOYS. FOR COMPLETE LIST CONT NEHC .
Stability Condition to Avoid:AVOID EXPOSING CYLS OF CARBON DIOXIDE TO
    EXTREMELY HIGH TEMPS, WHICH COULD CAUSE CYLS TO RUPTURE OR BURST.
Hazardous Decomposition Products:CARBON DIOXIDE GAS IN ELEC DISCHARGE
    YIELDS CARBON MONOXIDE & OXYGEN. IF PRESENCE OF MOISTURE, WILL FORM
    CARBONIC ACID.
Conditions to Avoid Polymerization:WILL NOT OCCUR, HOWEVER CARBON
    DIOXIDE ACTS TO CATALYZE POLYMERIZATION OF ACRYLADEHYDE &
    AZIRIDINE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:WASTE DISPOSAL MUST BE I/A/W APPROPRIATE
    FEDERAL, STATE & LOCAL REGULATIONS. RETURN CYLINDERS WITH ANY
    RESIDUAL PRODUCT TO AIRGAS. DO NOT DISPOSE OF LOCALLY.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their